Syncs network device inventory from Netdisco into Netbox, enriching existing Netbox device records with live data discovered by Netdisco.
Devices are matched by management IP. Hostnames are verified and a warning is logged on mismatch, but the sync proceeds regardless.
Netbox is written to directly via pynetbox for simplicity. Migration to Netbox Diode is a future consideration once its entity coverage matures.
discobox can be run in two modes:
A FastAPI server that receives webhook calls from Netdisco after each discovery and runs syncs in the background. Exposes Prometheus metrics and a Swagger UI.
# Docker
docker compose up -d discobox
# venv
python server.pySync a single device by IP directly from the command line. Useful for manual runs, testing, or scripting.
# Docker
docker compose run --rm cli --host 10.0.0.1
# venv
python cli.py --host 10.0.0.1--host <IP> Management IP of the device to sync (required)
--no-mac Skip MAC address sync
--no-ip Skip IP address sync
--no-modules Skip module bay / module sync
--no-sfp Skip SFP inventory item sync
--no-poe Skip PoE mode sync
--housekeeping Remove stale device bays and empty dummy interfaces
--debug Enable debug logging
- Device fields — updates serial number, OS version, OS name, OS release (parsed from description)
- Interfaces — creates and updates all physical and logical interfaces; maps interface type by name prefix; links subinterfaces (e.g.
Gi0/0/1.100) to their parent interface - PoE — sets
poe_mode = pseon ports reported as PoE-capable by Netdisco - MAC addresses — creates
dcim.mac-addressesobjects and links them as primary MAC per interface (Netbox 4.x model) - IP addresses — assigns interface IPs; fixes prefix mismatches (e.g.
/32→/26); moves IPs from dummy placeholder interfaces to the correct one - Module bays & modules — models physical chassis members as module bays with installed modules; assigns interfaces to their parent module
- Blades — models linecards, supervisors, and fabric modules as module bays on the device they belong to (routed per VSS member for split chassis)
- Device type auto-creation — creates manufacturer, device type (with part number and slug) if not present in Netbox
- SFP / transceiver inventory — creates inventory items for transceivers with serial numbers, linked to their interface
- PSU inventory — creates inventory items for power supplies
- HA / VIP detection — detects cluster VIPs by hostname mismatch; redirects sync to the real active node; creates a Virtual Chassis linking both HA members; optionally deletes the VIP device (housekeeping)
- Housekeeping — removes stale device bays auto-created from DeviceType templates (e.g.
PS-A,Fan 1,Slot 1) and deletes empty dummy interfaces
| Topology | Detection | Netbox model |
|---|---|---|
| Standalone | Single chassis, no stack root | Updates device_type directly on the device |
| Traditional stack (e.g. Cisco 3850) | class=stack root present |
Module bay + module per stack member; interfaces linked to their member's module |
| Nexus FEX (e.g. N9K-C93180LC-EX) | Stack root type cevContainerNexusLogicalFabric |
Primary N9K updates device_type; each FEX unit becomes a module bay + module; FEX interfaces linked to their FEX module |
| Cat9500 / Cat9600 StackWise Virtual | Stack root type contains VirtualStack or name contains Virtual Stack |
Two separate Netbox devices linked via Virtual Chassis; each gets its own blades and device type; partner found by serial or hostname (-2 suffix) |
| HA pair / VIP (e.g. Fortinet) | SNMP hostname differs from Netbox device found by IP, or hostname contains p1h/p2h, node1/node2, or -1/-2 |
Virtual Chassis created linking both physical nodes and the VIP device (p0h). Management VIP IP stays on the VIP device record; interface VIPs are assigned to whichever physical node syncs first. All shared IPs get role=vip. Behaviour of the VIP device is controlled by DISCOBOX_VIP_MODE (see Configuration). |
| Modular chassis (e.g. N9K-C9508, C9606R) | Standalone with class=module blade entries |
Blades (linecards, supervisors, fabric modules) modelled as module bays |
| Netdisco field | Netbox field |
|---|---|
serial |
serial |
os_ver |
custom_fields.os_version |
os |
custom_fields.os_name |
OS release (parsed from description) |
custom_fields.os_release |
Chassis model |
device_type.model |
Chassis type (vendor prefix) |
device_type.manufacturer |
| Netdisco field | Netbox field |
|---|---|
port / descr |
name |
| Interface name prefix | type (e.g. 10gbase-x-sfpp, lag, virtual) |
speed |
speed (kbps) |
duplex |
duplex |
description |
description |
up |
enabled |
mac |
dcim.mac-addresses → primary_mac_address |
| Netdisco field | Netbox field |
|---|---|
alias / ip + subnet |
ipam.ip-addresses.address (CIDR) |
| Interface port name | assigned_object (dcim.interface) |
| Netdisco field | Netbox field |
|---|---|
Chassis name |
Module bay name |
Chassis pos |
Module bay position |
Chassis model |
Module type model / part_number |
Chassis serial |
Module serial |
Chassis type vendor prefix |
Module type manufacturer |
| Netdisco field | Netbox field |
|---|---|
Module name |
Module bay name |
Slot number (from name) |
Module bay position |
Module model |
Module type model / part_number |
Module serial |
Module serial |
| Netdisco field | Netbox field |
|---|---|
Module name (expanded) |
Inventory item name + interface link |
Module model |
Inventory item part_id |
Module serial |
Inventory item serial |
Copy .env.example to .env and fill in the values:
NETDISCO_URL=https://netdisco.example.com
NETDISCO_USERNAME=admin
NETDISCO_PASSWORD=secret
NETBOX_URL=https://netbox.example.com
NETBOX_TOKEN=your-token-here
# Server mode
DISCOBOX_PORT=8080 # default: 8080
DISCOBOX_WORKERS=4 # uvicorn worker count, default: 4
DISCOBOX_AUTH_TOKEN=secret # bearer token for /sync; leave unset to disable auth
# Sync feature defaults (server mode) — can be overridden per-request
DISCOBOX_NO_MAC=true # disable MAC sync globally
DISCOBOX_NO_IP=true # disable IP sync globally (e.g. if Netdisco is not VRF-aware)
DISCOBOX_NO_MODULES=true # disable module bay sync globally
DISCOBOX_NO_SFP=true # disable SFP inventory sync globally
DISCOBOX_NO_POE=true # disable PoE sync globally
DISCOBOX_HOUSEKEEPING=true # enable housekeeping globally
# HA / VIP device handling — controls what happens to the VIP placeholder device (e.g. p0h)
# threenode (default) — add VIP device as VC member at pos 0; management VIP IP stays on it (role=vip)
# soft — unassign all IPs from VIP device so physical nodes can claim them; keep device
# hard — delete VIP device entirely
# off — do nothing
DISCOBOX_VIP_MODE=threenodevenv setup:
python3 -m venv .venv
source .venv/bin/activate
pip install -r requirements.txt
set -a && source .env && set +a| Endpoint | Method | Auth | Description |
|---|---|---|---|
/sync?host=<ip> |
GET, POST | yes | Trigger device sync |
/metrics |
GET | no | Prometheus metrics |
/health |
GET | no | Liveness check + in-flight hosts |
/docs |
GET | no | Swagger UI |
All sync flags are available as query parameters or JSON body fields, defaulting to the env var values:
POST /sync?host=10.0.0.1&housekeeping=true&sync_mac=false
POST /sync {"host": "10.0.0.1", "housekeeping": true, "sync_mac": false}
Syncs run in a background thread pool. Duplicate requests for the same host are dropped while a sync is in progress. Concurrent syncs log under discobox.<ip> so they are distinguishable in the log stream.
Add to your Netdisco config.yml to trigger a sync automatically after each device discovery:
hooks:
- event: discover
action: HTTP
url: "http://discobox:8080/sync?host=[% device.ip %]"
method: POST
headers:
Authorization: "Bearer your-token"
timeout: 30000Traditional stack — Cisco C9300 (3-member)
INFO discobox ── device 10.10.1.1
INFO discobox Netdisco hostname='SWCORE01-STK.corp.example.com' ports=167
INFO discobox Netbox device='swcore01-stk.corp.example.com' id=443
INFO discobox Device fields updated — serial='FOC2404H5VQ' os_name='ios-xe' os_ver=None os_release='Amsterdam'
INFO discobox stack (root) 'c93xx Stack' model=C9300-24UX serial=FOC2404H5VQ
INFO discobox ├── chassis 'Switch 1' model=C9300-24UX serial=FOC2404H5VQ
INFO discobox ├── chassis 'Switch 2' model=C9300-24T serial=FCW2352M8JP
INFO discobox └── chassis 'Switch 3' model=C9300-24T serial=FCW2352R3TN
INFO discobox Modules chassis=3 topology=stack
INFO discobox Switch 1 C9300-24UX serial=FOC2404H5VQ created
INFO discobox Switch 2 C9300-24T serial=FCW2352M8JP created
INFO discobox Switch 3 C9300-24T serial=FCW2352R3TN created
INFO discobox Modules — updated=3 unchanged=0 errors=0
INFO discobox PSUs entries: 3
INFO discobox PSU Switch 2 - Power Supply A model=PWR-C1-350WAC-P serial=DCC2344W9KR created
INFO discobox PSU Switch 3 - Power Supply A model=PWR-C1-350WAC-P serial=DCC2344B4QM created
INFO discobox PSU Switch 1 - Power Supply A model=PWR-C1-1100WAC-P serial=DCC2344L7FN created
INFO discobox PSUs — created=3 updated=0 unchanged=0 errors=0
INFO discobox GigabitEthernet2/0/4 created
INFO discobox Vlan653 created
INFO discobox TenGigabitEthernet1/0/12 updated
INFO discobox GigabitEthernet3/0/15 created
...
INFO discobox TenGigabitEthernet1/0/3.10 created
WARNING discobox StackPort1/1 in Netbox but not in Netdisco
WARNING discobox StackPort1/2 in Netbox but not in Netdisco
INFO discobox Subinterfaces — linked 1 parent(s)
INFO discobox Interface→Module — updated=124 unchanged=0 skipped=44
WARNING discobox IP 192.168.63.11/24 already in Netbox (id=2688, assigned to unassigned) — skipping
INFO discobox IP 172.16.56.1/26 → created on Vlan720
...
INFO discobox IPs — created=22 fixed=1 moved=0 unchanged=0 skipped=12 errors=0
INFO discobox SFPs entries: 12
INFO discobox SFP Te2/1/3 model=SFP-10G-SR-S serial=ACW2402P6SM → created
INFO discobox SFP Te3/1/8 model=SFP-10G-SR serial=AGA16034T3N → created
...
INFO discobox SFPs — created=12 updated=0 unchanged=0 errors=0
INFO discobox PoE — updated=0 unchanged=24 skipped=0 errors=0
INFO discobox ── done 10.10.1.1 created=140 updated=26 unchanged=0 errors=0
INFO discobox.server Sync success for 10.10.1.1 in 214.7s
StackWise Virtual — Cisco C9500 (2-member VSS)
INFO discobox.server hook from 10.10.0.5: 10.10.2.87 queued
INFO discobox ── device 10.10.2.87
INFO discobox Netdisco hostname='SWDIST01-VSS1.corp.example.com' ports=106
INFO discobox Netbox device='swdist01-vss1.corp.example.com' id=507
INFO discobox Device fields updated — serial='FDO25031N7Q' os_name='ios-xe' os_ver=None os_release='Amsterdam'
INFO discobox stack (root) 'Virtual Stack' model= serial=
INFO discobox ├── chassis 'Switch 2 Chassis' model=C9500-24Y4C serial=FDO25031B4R
INFO discobox └── chassis 'Switch 1 Chassis' model=C9500-24Y4C serial=FDO25031N7Q
INFO discobox Modules chassis=2 topology=vss
INFO discobox DeviceType → Cisco / C9500-24Y4C serial=FDO25031N7Q updated
INFO discobox VSS partner found by hostname 'swdist01-vss2.corp.example.com'
INFO discobox VSS partner DeviceType → C9500-24Y4C serial=FDO25031B4R updated
INFO discobox VirtualChassis 'SWDIST01-VSS1' — created
INFO discobox Modules — updated=2 unchanged=0 errors=0
...
INFO discobox ── done 10.10.2.87 created=0 updated=0 unchanged=105 errors=0
INFO discobox.server Sync success for 10.10.2.87 in 20.3s
Modular chassis — Cisco Nexus 9508 (blades + PSUs)
INFO discobox.server hook from 10.10.0.6: 10.10.3.21 queued
INFO discobox ── device 10.10.3.21
INFO discobox Netdisco hostname='NXCORE01-DC1' ports=570
INFO discobox Netbox device='nxcore01-dc1.corp.example.com' id=534
WARNING discobox Hostname mismatch for 10.10.3.21 — Netdisco='NXCORE01-DC1' Netbox='nxcore01-dc1.corp.example.com'
INFO discobox Device fields updated — serial='FGE22124W6T' os_name='nx-os' os_ver=None os_release=None
WARNING discobox Dummy interface 'mgmt0' still has 1 IP(s) — skipping deletion
INFO discobox Housekeeping — deleted 0 stale device bay(s), 0 empty dummy interface(s)
INFO discobox chassis (root) 'Nexus9000 C9508 (8 Slot) Chassis' type=cevChassisN9Kc9508 model=N9K-C9508 serial=FGE22124W6T
INFO discobox └── chassis 'Nexus9000 C9508 (8 Slot) Chassis' model=N9K-C9508 serial=FGE22124W6T
INFO discobox Modules chassis=1 topology=standalone
INFO discobox DeviceType → Cisco / N9K-C9508 serial=FGE22124W6T updated
INFO discobox Modules — updated=1 unchanged=0 errors=0
INFO discobox PSUs entries: 6
INFO discobox PSU PSU 1 model=N9K-PAC-3000W-B serial=ART2216B3QN created
INFO discobox PSU PSU 2 model=N9K-PAC-3000W-B serial=ART2216C8RM created
INFO discobox PSU PSU 3 model=N9K-PAC-3000W-B serial=ART2216D5WP created
INFO discobox PSU PSU 4 model=N9K-PAC-3000W-B serial=ART2216J4TS created
INFO discobox PSU PSU 5 model=N9K-PAC-3000W-B serial=ART2213K7VP created
INFO discobox PSU PSU 6 model=N9K-PAC-3000W-B serial=DTM214009XM created
INFO discobox PSUs — created=6 updated=0 unchanged=0 errors=0
INFO discobox Blades entries: 12
INFO discobox Blade Supervisor Module 1 model=N9K-SUP-B+ serial=FOC22203T8L created
INFO discobox Blade Supervisor Module 2 model=N9K-SUP-B+ serial=FOC222030S4 created
INFO discobox Blade 32p 40/100G Ethernet Module 1 model=N9K-X9732C-EX serial=FOC22191Q4T created
INFO discobox Blade 32p 40/100G Ethernet Module 2 model=N9K-X9732C-EX serial=FOC21186S7K created
INFO discobox Blade 32p 40/100G Ethernet Module 3 model=N9K-X9732C-EX serial=FOC22191P5N created
INFO discobox Blade 32p 40/100G Ethernet Module 4 model=N9K-X9732C-EX serial=FOC27028M3L created
INFO discobox Blade Fabric Module 2 model=N9K-C9508-FM-E serial=FOC22191R2M created
INFO discobox Blade Fabric Module 3 model=N9K-C9508-FM-E serial=FOC21410B9R created
INFO discobox Blade Fabric Module 4 model=N9K-C9508-FM-E serial=FOC21410C4P created
INFO discobox Blade Fabric Module 6 model=N9K-C9508-FM-E serial=FOC21410D8N created
INFO discobox Blade System Controller 1 model=N9K-SC-A serial=FOC22155G3Q created
INFO discobox Blade System Controller 2 model=N9K-SC-A serial=FOC22155H7X created
INFO discobox Blades — created=12 updated=0 unchanged=0 errors=0
INFO discobox Ethernet4/20 created
INFO discobox Tunnel26 created
INFO discobox Tunnel211 created
...
HA pair / VIP — Fortinet (threenode mode)
INFO discobox Netbox device='fwcluster01p1h.corp.example.com' id=24761
INFO discobox.10.10.4.98 HA VIP device 'fwcluster01p0h.corp.example.com' added as VC member pos=0
INFO discobox VC member fwcluster01p1h.corp.example.com pos=1 unchanged
INFO discobox VC member fwcluster01p2h.corp.example.com pos=2 unchanged
INFO discobox VC member fwcluster01p0h.corp.example.com pos=0 unchanged
INFO discobox.10.10.4.98 HA peer VirtualChassis 'fwcluster01' — unchanged (topology=standalone per Netdisco; VC is Netbox-side)
INFO discobox.10.10.4.98 VIP device 'fwcluster01p0h.corp.example.com' — device_type updated
INFO discobox.10.10.4.98 VIP device 'fwcluster01p0h.corp.example.com' — primary IP 10.10.4.97/24 role set to vip
INFO discobox Device fields updated — serial='FG6H0FTB24913847' os_name='fortios' os_ver=None os_release=None