assumeConstantDensity=false causes a nonlinear equation system for ThermofluidStream.Boundaries.DynamicPressureInflow
ThermofluidStream.Boundaries.DynamicPressureOutflow and
ThermofluidStream.Processes.Nozzle.

I added the parameters dp_start, p_start, T_start to provide start values for this NLE. One could add the start values individualy on text layer, but i think thats rather inconvenient.

….p_out since they mainly occur for assumeConstantDensity=false. saves work
@RaphaelGebhart

Copy link
Copy Markdown
Collaborator Author

Converted to draft, as I need to review this PR again before proceeding.