0.3.14

  • Modbus TCP Client (active mode): handles multiple responses received in a single tcp packet.
  • Modbus TCP Server: handles multiple requests received in a single tcp packet.
  • Modbus TCP Client & Server: reassemble requests/responses split across tcp packets.
  • Modbus TCP Client: pending requests are discarded when the connection is closed.

0.3.13

  • Modbus TCP: the protocol identifier other than Modbus (0x00, 0x00) has been relaxed and logged.

0.3.12

  • Improve bitstring logging.

0.3.11

  • Elixir 1.15 (OTP 26) warnings fixed.