DeviceNotFoundError when it was working a moment ago

If a session was running fine and then the device vanishes mid-run, the usual advice in that error message does not apply - Cortex Control is quit, the cable is in, and the unit has booted. What can happen instead is that the unit's USB link dies and only a full power-down recovers it.

This is field experience from one unit, not a protocol finding, and the root cause is unknown. Recorded because the symptoms are misleading and cost a user about an hour.

What it looks like: hid.enumerate() reports zero Neural DSP interfaces and connect() raises. Reseating the cable at either end changes nothing, and retrying in software never succeeds (25 attempts over 75 seconds, never visible once).

How to tell it apart from a plain disconnection: the port is flapping - asserting and dropping a connection several times a second - rather than idle. On macOS:

log show --last 60s --predicate 'eventMessage CONTAINS "cableChangeOccurred"' \
    --style compact | grep -c cableChangeOccurred

Hundreds of events a minute with nobody touching the cable means the connection is being made and lost repeatedly, so enumeration never completes. Roughly 264 events were seen while attached, against about 1 per minute with the cable out - which is also a clean way to exonerate the host: if it is quiet with nothing plugged in, the Mac's port and USB stack are fine.

What fixed it: a full shutdown of the unit, then power on. A reboot was not enough, and unplugging at the unit end does not reset its USB controller either.

Then wait about three minutes before re-diagnosing. After a restart the link flaps for a while as it settles, and that looks identical to the fault: in one measurement the unit was still flapping a minute later with zero interfaces, then enumerated on its own two and a half minutes after the restart with no intervention. Sampling during that window twice led a user to wrongly conclude the power cycle had failed.

What is not established: the cause. One unit, one host, and only ever the cable that shipped with it, so a marginal cable is not ruled out. Onset followed roughly 20 minutes of continuous heavy write traffic, though whether that is connected is unknown.

The rig is silent (or clicking) and every read-back looks perfect

See "Settings only your ears can verify" in api.md. The short version: any host write to the Tuner subsystem engages an invisible tuner state - combined with the tuner's mute preference, the outputs go silent with no on-screen cause, and only opening and closing the tuner on the unit releases it. A faint metronome click means the transport (tempo parameter 4) is running - 1.0 is RUNNING, and the volume control's floor is -60 dB, not silence. None of this is visible to a read: the values read back exactly as written.

How long a reboot or cold boot actually takes

Measured on d14e: a reboot is ~39 s not enumerated, then ~9 s enumerated-but-silent, then a ~2 s handshake - about 55 s total, and connect() rides through the silent window on its own (handshake_patience). A cold boot showed ~11.7 s of silent-but-openable. If a unit is unreachable for MINUTES, that is not a boot - see the USB-link-death section.