omotion — Public API / Interface Guide

How a host application or script drives the Open-Motion system through the omotion package. This is the consumer-facing interface: connect to hardware, run scans, read the data back, and (optionally) plug into the processing pipeline. For internals (transport framing, FPGA programming, the science of the pipeline) see Architecture.md, SciencePipeline.md, and ScanDatabase.md.

One entry point: omotion.MotionInterface. Everything else hangs off it. Apps construct it once, start() it, hold the handles, and connect signals.


Contents

  1. Quick start
  2. MotionInterface — the facade
  3. Running a scan
  4. Configure / contact quality / calibration
  5. Reading scans back — ScanDatabase
  6. Custom processing & replay — omotion.pipeline
  7. Signals & threading
  8. Constants — omotion.config
  9. Logging & versioning

1. Quick start

from omotion import MotionInterface
from omotion.ScanWorkflow import ScanRequest

iface = MotionInterface(
    data_dir="C:/scans",                 # output root (optional)
    operator_id="alice",
)
iface.start(wait=True, wait_timeout=3.0)  # discover + connect (spawns daemons)

console_ok, left_ok, right_ok = iface.is_device_connected()

iface.start_scan(ScanRequest(
    subject_id="subj-001",
    duration_sec=60,
    left_camera_mask=0xFF, right_camera_mask=0xFF,
))
iface.scan_workflow.await_complete()      # scans run on a worker thread
if iface.scan_workflow.last_scan_error:
    print("scan failed:", iface.scan_workflow.last_scan_error)

iface.stop()

Without hardware — pass demo_mode=True (or set env OPENMOTION_DEMO=1) to skip USB/serial discovery and generate synthetic data. The same API works headless; signals fall back from pyqtSignal to MotionSignal automatically.

iface = MotionInterface(demo_mode=True)
iface.start()

Runnable examples

scripts/sdk_examples.py drives each operation in this guide against connected hardware and prints the result. Run one, or all in sequence:

python scripts/sdk_examples.py connect          # §2  connect + version
python scripts/sdk_examples.py configure        # §4  configure cameras
python scripts/sdk_examples.py contact-quality  # §4  per-camera CQ verdicts
python scripts/sdk_examples.py scan             # §3  run a short scan
python scripts/sdk_examples.py scan --duration 60   # §3  run a 60s scan
python scripts/sdk_examples.py read-scan        # §5  summarize the scan DB
python scripts/sdk_examples.py test-scan        # §4  per-camera test rows
python scripts/sdk_examples.py                  # all of the above, one connection

(scan and test-scan turn the laser on; read-scan is read-only and needs no hardware. --duration (seconds) applies to scan / test-scan. Output lands under a temp directory printed at connect time.)

To plot a finished scan, scripts/visualize_scan.py renders BFI / BVI / mean / contrast over time (16 cameras, per-side average bold) from the corrected CSV the scan example writes:

python scripts/visualize_scan.py --csv <scan_id>_<subject>.csv   # -> <stem>_viz.png

2. MotionInterface — the facade

from omotion import MotionInterface

Construction

MotionInterface(
    vid: int = 0x0483,
    sensor_pid: int = SENSOR_MODULE_PID,     # 0x5A5A
    console_pid: int = CONSOLE_MODULE_PID,   # 0xA53E
    baudrate: int = 921600,
    timeout: int = 30,
    demo_mode: bool = False,
    default_trigger_config: dict | None = None,
    data_dir: str | None = None,
    scan_db_path: str | None = None,
    operator_id: str | None = None,
)
Param Purpose
demo_mode No hardware; synthetic data.
data_dir Output root. When set, scans auto-write CSVs here (corrected/raw/telemetry, gated by the per-scan flags).
scan_db_path SQLite file. When set, scans auto-write session_data rows (the queryable record used for replay). Recommended over CSV.
operator_id Stamped into scan metadata / DB session meta.
default_trigger_config Overrides merged over the SDK trigger defaults for every scan.
vid / *_pid / baudrate USB/serial identifiers — defaults match production hardware.

data_dir and scan_db_path are independent: set either, both, or neither. With neither, a scan runs but persists nothing unless you supply your own sinks (see §6). If a scan_db_path is set but the DB can't be opened, the scan is refused (no silent data loss) — see start_scan.

Lifecycle

Method Description
start(wait=True, wait_timeout=2.0) Begin discovery, open the console + both sensors, start the hotplug monitor (daemon thread). With wait, blocks up to wait_timeout for the first connection.
stop() Tear down monitor + transports. Idempotent.

Device handles (stable for the process lifetime)

Attribute Type What it is
console MotionConsole UART device — trigger, TEC, fan, FPGA, telemetry.
left, right MotionSensor USB devices — cameras, histograms, IMU, DFU.

These are created once and never replaced, so apps cache them and connect their signals once. Their full command sets live in MotionConsole / MotionSensor (see Architecture.md) — most consumers only touch them through the workflows below.

Connection state

Method Returns
is_device_connected() (console_ok, left_ok, right_ok) bools.
connected_sensors() List of connected MotionSensors.
wait_for_ready(...) Block until the requested handles report ready.

Workflow entry points

Method / property Purpose
start_scan(request) -> bool Launch a scan (see §3).
cancel_scan(**kw) Stop the running scan.
start_configure_camera_sensors(request) -> bool Program/enable cameras (see §4).
start_calibration(request) -> bool / start_test_scan(request) Calibration / validation (see §4).
apply_laser_power(*, force_fault=False) -> bool Write laser-driver config over I2C — a cold-start prerequisite for any laser scan (see §3).
get_single_histogram(side, camera_id, test_pattern_id=4, auto_upload=True) One-shot histogram grab.
scan_workflow The ScanWorkflow instance (lazy).
calibration_workflow / contact_quality_workflow The other workflows (lazy; CQ shares the scan workflow).

start_scan / start_calibration / start_configure_camera_sensors are thin forwarders onto scan_workflow; use the property directly when you need to poll state or call await_complete().


3. Running a scan

A scan runs asynchronously on a worker thread. start_scan returns True once the worker is spawned (or False if it refused — see below); use the scan_workflow properties to observe progress and completion.

Laser-power cold start. After a power-cycle the laser-driver registers are cleared, so the trigger fires but no light is emitted — scans complete but produce no signal. Call iface.apply_laser_power() once after connecting and before the first laser scan (scan / contact-quality / calibration / test). It writes the SDK's bundled laser config over I2C and persists in the firmware until the next power-cycle. (The bloodflow app does this automatically; raw SDK consumers must call it themselves.)

ScanRequest

from omotion.ScanWorkflow import ScanRequest

@dataclass
class ScanRequest:
    subject_id: str
    duration_sec: int
    left_camera_mask: int            # bit i set = camera i enabled
    right_camera_mask: int
    disable_laser: bool = False
    expected_size: int = 32837
    write_corrected_csv: bool = True # opt out when the DB is the system of record
    write_telemetry_csv: bool = True
    reduced_mode: bool = False       # per-side averaged BFI/BVI instead of per-camera
    sinks: list = field(default_factory=list)        # custom pipeline sinks (§6)
    skip_default_storage: bool = False               # don't auto-inject CSV/DB sinks
    raw_save_max_duration_s: float | None = None     # cap raw output; 0 = no raw
    batch_size_frames: int = 10
    trigger_config: dict | None = None               # override; None = interface default

start_scan (re)sends the resolved trigger config before starting the trigger, which resets the firmware fsync/dark-frame schedule so dark correction stays aligned — so you normally never need to set trigger_config.

reduced mode is the clinical path: the pipeline averages the active cameras into one left + one right BFI/BVI value per capture. In reduced mode the scan DB stores only the per-side average (cam_id = -1 rows), not per-camera rows.

start_scan

ok = iface.start_scan(request)   # -> bool

Returns False (scan refused, never started) when a previous scan is still running or the configured scan DB fails its pre-flight open. When the DB is the only record (corrected CSV opt-in/off), this refusal is deliberate — it aborts before the laser fires rather than run a scan whose data is lost. The reason is on scan_workflow.last_scan_error.

Observing & finishing

iface.scan_workflow exposes:

Member Meaning
running (bool) A scan worker is active.
await_complete(timeout_sec=None) Block until the worker exits.
cancel_scan(join_timeout=5.0) User-stop with orderly teardown.
last_scan_error (str | None) Error from the most recent scan, else None.
last_scan_canceled (bool) True if the most recent scan was user-canceled.
current_scan_label (str | None) "{scan_id}_{subject_id}" of the most recent scan — the DB session_label, valid as soon as start_scan returns.

ScanResult (the per-scan outcome object, surfaced via the legacy callback path and the calibration workflow) carries ok, error, canceled, scan_timestamp, the CSV paths, and dark_integrity_warnings.

Where the data goes

  • CSV (if data_dir set): corrected, raw (duration-capped), and telemetry CSVs, gated by the per-scan flags. Corrected CSV is opt-in when a DB is set.
  • Scan DB (if scan_db_path set): session_data rows per frame — per-camera BFI/BVI/mean/contrast/temp in normal mode, or the per-side average (cam_id=-1) in reduced mode. This is what §5 reads back for replay.

4. Configure / contact quality / calibration

Configure cameras

from omotion.ScanWorkflow import ConfigureRequest
iface.start_configure_camera_sensors(
    ConfigureRequest(left_camera_mask=0xFF, right_camera_mask=0xFF,
                     power_off_unused_cameras=False))

Contact quality

iface.contact_quality_workflow.check(duration_sec=..., rolling_window=..., dark_threshold_per_camera=..., light_threshold_per_camera=...) runs a short acquisition and reports per-camera ambient-light / poor-contact status. It is a pipeline consumer that maintains its own rolling-window average.

Calibration & test

from omotion import CalibrationRequest, factory_calibration_thresholds
iface.start_calibration(CalibrationRequest(          # computes per-camera C_max / I_max
    ..., thresholds=factory_calibration_thresholds()))
iface.start_test_scan(request)                       # validates against thresholds

Calibration (c_min, c_max, i_min, i_max, source) is the affine map the pipeline uses for BFI/BVI. The connected console's calibration is loaded at connect; iface.scan_workflow.set_realtime_calibration(...) overrides it. CalibrationResult / CalibrationResultRow / CalibrationThresholds describe the outcome and the pass/fail gates. factory_calibration_thresholds() is the canonical WI-00015/SPEC-69 acceptance set — start from it instead of writing your own numbers. If any camera misses any threshold the whole run FAILS and the console EEPROM is never written: the proposed calibration is applied to the SDK's in-memory cache for the validation scan, and the EEPROM write happens only after a fully-passing validation — there is no operator override and no rollback. Thresholds that cannot fail the pre-write gate (min mean/contrast missing or ≤ 0 for an active camera — e.g. all-zero lists) are refused by start_calibration, which returns False and reports why through on_log_fn: a gate that can't fail would let a below-spec calibration onto the console while reporting PASSED (#256). A deliberate ungated bench run must say so with CalibrationRequest(allow_ungated=True). start_test_scan writes nothing and is not guarded.


5. Reading scans back — ScanDatabase

from omotion import ScanDatabase

Open the same SQLite file the scan wrote, read-only is fine for replay:

db = ScanDatabase(db_path="C:/scans/scans.db")
for s in db.iter_sessions():                 # {id, session_label, session_start, ...}
    print(s["id"], s["session_label"])

session = db.get_session_by_label("20260528_211930_subj-001")
for row in db.iter_session_data(session["id"], t_lo=0.0, t_hi=30.0):
    # row: cam_id, side(0/1), frame_id, timestamp_s, bfi, bvi, mean, contrast, temp
    ...
db.close()

Key read methods:

Method Purpose
iter_sessions() / stream_sessions(batch_size=100) All sessions, oldest first.
get_session(id) / get_session_by_label(label) One session.
iter_session_data(session_id, side=None, cam_id=None, t_lo=None, t_hi=None) Per-frame BFI/BVI/mean/contrast/temp; optional side/camera/time-range filters.
iter_raw_frames(...) / get_raw_frame(id) Raw histograms (only if write_raw_to_db).

session_data layout: cam_id 0..7 are per-camera rows (normal mode); cam_id = -1 is the reduced-mode dark-corrected per-side average (one per capture per side). side is 0 = left, 1 = right.

omotion.materialize_corrected_csv(...) rebuilds a corrected CSV from a DB session (legacy-format export / playback).


6. Custom processing & replay — omotion.pipeline

Most consumers never touch this — the workflows assemble it for you. Reach here to replay recorded data through the pipeline, or to tap the live stream with a custom sink.

from omotion.pipeline import (
    default_pipeline, ScanRunner, ScanMetadata, SensorPedestals,
    CsvReplaySource, CsvSink, ScanDBSink, CriticalSinkError,
)

A run is Source → Pipeline → Sinks, driven by ScanRunner:

meta = ScanMetadata(scan_id="x", subject_id="y", operator="z",
                    started_at_iso="...", duration_sec=60,
                    left_camera_mask=0xFF, right_camera_mask=0xFF, reduced_mode=False)
pipeline = default_pipeline(metadata=meta, calibration=cal,
                            pedestals=SensorPedestals(left=64.0, right=64.0))
source = CsvReplaySource(raw_csv_left="left.raw.csv", raw_csv_right=None,
                         batch_size_frames=20, metadata=meta)
ScanRunner(source=source, pipeline=pipeline, sinks=[CsvSink(output_dir="./out")]).run()

Sinks & channels

A sink subscribes to channels and receives the pipeline's output:

class MySink:
    channels = {"live"}          # which channels to receive
    critical = False             # True → a failed on_scan_start aborts the scan
    def on_scan_start(self, meta): ...
    def consume(self, channel, payload): ...   # payload depends on the channel
    def on_complete(self): ...
Channel Payload Cadence
"raw" FrameBatch (raw histograms) per batch
"live" FrameBatch after BFI/BVI (realtime) per batch
"live_side" SideAverageSample (realtime per-side avg) per capture, reduced mode
"final" EnrichedCorrectedInterval (dark-corrected frames; in reduced mode also the cam_id=-1 side-average intervals) per closed dark interval (~15 s)
"diagnostics" BatchEvent (e.g. DarkIntegrityWarning, trigger transitions) as they occur

SideAverageSample carries t, frame_id, side, bfi, bvi. A sink whose on_scan_start raises is disabled for the scan unless it sets critical = True, in which case ScanRunner raises CriticalSinkError and the scan aborts (this is how ScanDBSink guarantees no silent data loss). Pass custom sinks via ScanRequest.sinks (+ skip_default_storage=True to suppress the auto-injected CSV/DB sinks).

Sources: LiveUsbSource (hardware), CsvReplaySource (raw CSV — the only raw record; the scan DB stores corrected data only). See SciencePipeline.md for the stage chain.


7. Signals & threading

Device handles emit events via signals. When PyQt6 is importable they are real pyqtSignals; otherwise they are MotionSignal objects with the same .connect() / .emit() API — so headless scripts behave like the GUI apps.

Up to three daemon threads run concurrently after start(): the hotplug ConnectionMonitor, the per-endpoint stream readers, and the telemetry poller. Scans add a worker thread. Signals fire from these threads — UI code must marshal to the main thread (the apps use Qt.QueuedConnection). Connection transitions surface as ConnectionState updates on the handles.


8. Constants — omotion.config

from omotion import config (or from omotion.config import *). Single source of truth for wire-level values:

Name Value Meaning
CONSOLE_MODULE_PID 0xA53E Console USB PID (VID 0x0483).
SENSOR_MODULE_PID 0x5A5A Sensor USB PID.
BAUD_RATE 921600 Console UART baud.
HISTO_SIZE_WORDS 1024 Histogram bins.
OW_ACK/OW_CMD/OW_DATA/… Packet type bytes (shared protocol).
DEBUG_FLAG_* bit flags Firmware debug toggles (FAKE_DATA, HISTO_THROTTLE, HISTO_CMP, USB_PRINTF, …).

Debug flags are pushed to firmware with MotionSensor.set_debug_flags(...).


9. Logging & versioning

  • omotion.set_log_root("MyApp") prefixes every SDK logger name (e.g. MyApp.Console). Call it before start().
  • omotion.__version__ is derived from git tags (setuptools_scm) — never hand-edited.