Skip to content

Misleading time signal plot when quantizing stereo signals #6

Description

@martinholters

The signal plots are derived from a mono-downmix. Hence, when a stereo signal is processed with the quantization script, the time domain signal plot shows additional levels in between the quantization levels. If e.g. for a 2-bit quantizer, a sample is quantized to 0 in the left channel and to 0.5 in the right channel, the plot will show a value of 0.25, which should not occur with 2-bit quantization.

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions