Skip to content

Commit 7ba673a

Browse files
Merge branch 'JIRA-ANF-63484' of github.com:netapp-manishc/azure-docs-pr into JIRA-ANF-63484
2 parents 93fb985 + 00597ba commit 7ba673a

1 file changed

Lines changed: 2 additions & 2 deletions

File tree

articles/azure-netapp-files/cool-access-introduction.md

Lines changed: 2 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -5,7 +5,7 @@ services: azure-netapp-files
55
author: b-ahibbard
66
ms.service: azure-netapp-files
77
ms.topic: how-to
8-
ms.date: 10/02/2025
8+
ms.date: 03/05/2026
99
ms.author: anfdocs
1010
ms.custom: references_regions
1111
# Customer intent: As a storage administrator, I want to configure inactive data to move from a hot tier to a cool tier in Azure NetApp Files, so that I can optimize storage costs while maintaining accessibility to archived data.
@@ -30,7 +30,7 @@ After data blocks are marked "cold," the tiering scan collects the blocks and pa
3030
> [!NOTE]
3131
> When you enable cool access, data that satisfies the conditions set by the coolness period moves to the cool tier. For example, if the coolness period is set to 30 days, any data that was cool for at least 30 days moves to the cool tier _when_ you enable cool access. Once the coolness period is reached, background jobs can take up to 48 hours to initiate the data transfer to the cool tier.
3232
33-
By default (unless cool access retrieval policy is configured otherwise), data blocks on the cool tier that are read randomly again become "warm" and are moved back to the hot tier. After the data blocks are marked as "warm," they're again subjected to the temperature scan. Large sequential reads (like index and antivirus scans) on inactive data in the cool tier don't "warm" the data. They also don't trigger inactive data so that it moves back to the hot tier.
33+
By default (unless cool access retrieval policy is configured otherwise), data blocks on the cool tier that are read randomly again become "warm" and are moved back to the hot tier. After the data blocks are marked as "warm," they're again subjected to the temperature scan. Large sequential reads (like index and antivirus scans) on inactive data in the cool tier don't "warm" the data.
3434

3535
Metadata is never cooled and always remains in the hot tier. Tiering doesn't affect the activities of metadata-intensive workloads like high file-count environments like chip design, version control systems, and home directories.
3636